Applications

A 128-electrode high-density ECoG array on the speech cortex of a person with anarthria after a brainstem stroke, decoding a 50-word vocabulary into sentences in real time at 15.2 words per minute. NEJM, 2021.

Application — Cortical surface

Speech neuroprosthesis for anarthria (Moses, 2021)

speech · ECoG · anarthria · brainstem stroke · percutaneous connector · 128 electrodes · academic · human

Speech neuroprosthesis for anarthria (Moses, 2021)

One-line verdict: A surface-array speech decoder. Slow and limited to 50 words, but with signals that stayed stable over 81 weeks.

Quick tags: Recording · Cortical surface · Human · NEJM 2021 (385:217-227)


Overview

What it is: A neuroprosthesis for decoding speech in a paralyzed person with anarthria (loss of the ability to articulate speech) and spastic quadriparesis from a brainstem stroke. It uses electrocorticography with custom decoding techniques. An FDA investigational device exemption covered the device.

Hardware: A customized combination of a high-density ECoG electrode array (manufactured by PMT) and a percutaneous connector (manufactured by Blackrock Microsystems). The rectangular array is 6.7 cm long, 3.5 cm wide and 0.51 mm thick, with 128 flat disk-shaped electrodes. It lies on the pial surface in the subdural space, covering several speech-related cortical regions. The connector passes signals through the skin to a detachable digital link and cable, so this is a wired system.

Study: Over 48 sessions, 22 hours of cortical activity were recorded as the participant attempted to say individual words from a 50-word vocabulary. The isolated-word task had 9,800 trials.

Results (as reported): Sentences were decoded in real time at a median 15.2 words per minute, with a median word error rate of 25.6% using a language model (60.5% without one). The lowest word error rate for a single sentence block was 7.0%. In post hoc analyses, 98% of attempts to produce individual words were detected, and words were classified with 47.1% accuracy using cortical signals that were stable throughout the 81-week study period.

Limits: One participant, a 50-word vocabulary, and a percutaneous connector.


Spec Card Grid

Identity

  • Paper: “Neuroprosthesis for decoding speech in a paralyzed person with anarthria,” N Engl J Med 2021;385:217-227
  • Participant: one person with brainstem stroke

Architecture

  • Array: 128 electrodes, 6.7 cm by 3.5 cm by 0.51 mm, subdural, made by PMT
  • Connector: percutaneous, Blackrock Microsystems
  • Vocabulary: 50 words

Results

  • Real-time sentences: median 15.2 words per minute, 25.6% word error rate with language model
  • Stability: signals stable across the 81-week study period

Evidence and limits


References